A broad-range measuring device allows for use of the test instrument in all alternating and 3-phase electrical systems with voltages from 65 to 500 V and frequencies of 15.4 to 420 Hz.
- Loop and line impedance measurement
 - Measurement of insulation resistance using nominal voltage, with variable or rising test voltage
 - Low-resistance measurement
 - Earth resistance measurement
 - Standing-Surface Insulation MeasurementBLUETOOTH Interface Logo
 - Universal connector system
 - Standard-compliant Testing of Electric Vehicle Charging Stations in accordance with IEC 60364-6 and IEC 61851
 
>
Testing of residual current devices (RCCBs)
- Measurement of contact voltage without tripping the RCCB
 - Contact voltage is measured with reference to nominal residual current using 1/3 of the nominal residual current value
 - Tripping test with nominal residual current, tripping time measurement
 
>
Special testing for systems and RCCBs
- Testing of equipment and RCCBs with rising residual current including indication of tripping current and contact voltage at the moment the RCCB is tripped
 - Testing of RCCBs with: 1/2x, 1x, 2x, 5x IΔN
 - Testing of RCCBs which are suitable for pulsating residual direct current, testing is conducted with positive or negative half-waves
 - Testing of RCCBs with adjustable residual current for determining contact voltage
 
>
Testing for special RCDs
- Selective S, SRCDs, PRCDs (Schukomat, Sidos and others), types G/R, AC, A, F, Type B, B , EV
 
>
Special features of the PROFITEST MASTER family
- EASY transfer stands for direct incorporation of the Profitest Master into DDS-CAD planning software
 - Display of approved fuse types for electrical systems
 - Programable test sequences
 - Energy meter start-up testing
 - Calculation of cable lengths for common copper wire cross-sections
 - Measurement of biasing, leakage and circulating current up to 1 A, as well as working current up to 150 A with the WZ12C current sensor clamp as an accessory
 - Phase sequence measurement (including highest line-to-line voltage)
 - Measurement of contact voltage without tripping the RCCB
 - Contact voltage is measured with reference to nominal residual current using 1/3 of the nominal residual current value
 - Tripping test with nominal residual current, tripping time measurement
 
>
Each Unit Includes
- 1 Test instrument
 - 1 Earthing contact plug insert (country-specific)
 - 1 2-pole measuring adapter and 1 cable for expansion into a 3-pole adapter (PRO-A3-II)
 - 2 Alligator clips
 - 1 Shoulder strap
 - 1 Set of rechargeable batteries (Z502H)
 - 1 Battery charger Z502R
 - 1 Condensed operating instructions
 - 1 Supplement Safety Information
 - 1 DAkkS calibration certificate
 - 1 USB cable
 
			        
                             