2 × $2,514.00
-
1 × $503.00
-
1 × $1,961.00
-
1 × $959.00
-
1 × $4,351.00
-
1 × $5,571.00
-
1 × $1,956.00
-
1 × $4,156.00
-
1 × $959.00
-
1 × $1,407.00
-
1 × $25,018.00
-
1 × $19,742.00
-
1 × $477.00
-
1 × $759.00
-
1 × $3,967.00
-
1 × $704.00
-
1 × $5,195.00
-
1 × $3,368.00
-
1 × $959.00
-
1 × $5,945.00
-
1 × $4,429.00
-
1 × $1,420.00
-
1 × $1,357.00
-
1 × $661.00
-
1 × $603.00
-
1 × $2,057.00
-
1 × $6,744.00
-
1 × $479.00
-
1 × $905.00
-
1 × $1,337.00
-
1 × $1,831.00
-
Keysight N1912A/101 Dual Channel Power Meter: Precision Power Measurement for Demanding Applications1 × $12,209.00
-
1 × $1,055.00
-
1 × $2,715.00
-
1 × $959.00
-
1 × $4,206.00
-
1 × $3,536.00
-
1 × $4,306.00
-
1 × $2,694.00
The Megger MIT515-US insulation resistance tester measures insulation resistance, voltage, current, and capacitance in high-voltage electrical systems. This multiranging digital meter performs timed insulation resistance (IR), polarization index (PI), and dielectric absorption ratio (DAR) tests.
- Smaller size and lighter weight allows easier transport and use without compromising performance.
- High measurement range enables installation testing and long-term trending of higher value apparatus.
- Unique dual case design allows for fire-retardant protection while maintaining ruggedness.
- High-quality, flexible silicon test leads meet safety regulations of IEC 61010-31:2008 while ensuring measurement accuracy.
- Timed IR plus PI, DAR, DD, SV and ramp tests maximize diagnostic testing capability.
- Operate from line power when battery fully discharged (charges while operating).
- Two and one-half hour full battery charge time (one half hour charge for one hour testing) significantly increases productivity.
- Up to six hours continuous testing (5 kV) on a single battery charge.
- Industry best guard terminal performance to insure highest accuracy of measured values.
- Enhanced driver technology provides plug-and-play when connected to the internet. No tedious and potentially interruptive setup procedures.
- Dedicated voltmeter function (30 V to 660 V) with frequency measurement allows the user to check for induced voltages.
- CATIV 600 V safety rating on all terminals allows for safe use in the widest range of applications.
- Large LCD with automatic backlight.
- Noise filter rejects up to 3 mA noise for effective operation in electrically noisy environments.
- High altitude operation up to 3000 m while maintaining CATIV 600 V rating.
- Rotary switch operation for easy, intuitive field use.
- Field replaceable battery
>
Each Unit Includes
- User guide CD
- Power lead
- 10 ft (3 m) leadset x 3, medium insulated clips