1 × $503.00
-
1 × $4,860.00
-
1 × $462.00
-
1 × $1,055.00
-
1 × $2,974.00
-
2 × $711.00
-
1 × $5,663.00
-
1 × $3,209.00
-
1 × $2,111.00
-
2 × $553.00
-
1 × $2,722.00
-
2 × $2,719.00
-
1 × $2,468.00
-
1 × $4,348.00
-
1 × $2,229.00
-
1 × $1,508.00
-
2 × $1,080.00
-
1 × $2,468.00
-
1 × $1,063.00
-
1 × $1,508.00
-
1 × $653.00
-
1 × $3,368.00
-
1 × $959.00
-
1 × $1,337.00
-
1 × $466.00
-
1 × $508.00
-
1 × $1,231.00
-
1 × $1,155.00
-
1 × $959.00
-
1 × $35,405.00
-
2 × $530.00
-
1 × $821.00
-
1 × $1,411.00
-
1 × $1,609.00
-
1 × $854.00
-
1 × $804.00
-
1 × $1,988.00
-
1 × $5,663.00
-
1 × $1,257.00
-
1 × $2,533.00
-
1 × $2,313.00
-
1 × $6,744.00
-
1 × $591.00
-
1 × $2,965.00
-
1 × $968.00
-
1 × $1,457.00
-
1 × $1,337.00
-
1 × $1,055.00
-
1 × $35,731.00
-
1 × $1,005.00
-
1 × $5,932.00
-
1 × $1,658.00
-
1 × $577.00
-
1 × $6,200.00
-
1 × $947.00
-
1 × $479.00
-
1 × $1,823.00
-
1 × $6,208.00
-
1 × $6,862.00
-
1 × $1,005.00
-
1 × $956.00
-
1 × $5,530.00
-
1 × $1,608.00
-
1 × $1,337.00
-
1 × $1,860.00
-
1 × $1,441.00
-
1 × $702.00
-
1 × $3,209.00
- Two functions in one: Insulation tester and ground fault locator
- Test and record insulation status of facilities
- Powerful management DataView Software on PC for data analysis
- No disconnection of the electrical installation ground fault location is carried out during operation
- Fast locations for ground fault even when cables are buried
- Signal-generator with adjustable frequency and voltage
- Reflects aging status of facilities for further reparation
- Reduced maintenance and repair costs
- Compact & rugged design
- Measuring range V testing: 0.00-1000V, Insulation resistance: 20kO-500MO (250V)
- 50kohms-1000Mohms (500V) 100 kohms-2000Mohms (1000V)
- Min resolution Voltage: 0.1V Insulation R: 0.01 Mohms
- Accuracy Voltage: 1%rdg±8dgt
- Insulation R: 0.5 Mohm-100 Mohm 5 rdg±6dgt?100 MO: 10%rdg±6dgt
- Output signal voltage: 0-1000V±10% Frequency: 1-1000Hz
- Power consumption =4 hours(continuous operation)
- Memory 32k×8bit Non Volatile SRAM
- Displaying screen 128×64 pixels LCD
- Communication USB interface
- Dimension 14.5L x 11.4W x 9.8H
- Humidity 80%R.H
- Testing accuracy =0.25Mohm
- Sensor aperture 2.3
- Battery Li-ion
- Weight 15.4 lbs.
- Temperature 23°F to 104°F
- Power voltage DC 8.4V
- Jaw opening 2.6
>
Each Unit Includes
- GFL-1000 Main Body Signal Generator
- Power Adapter
- Two (2) Signal Testing Leads
- Two (2) Alligator Clips
- Punctuation Clip
- Signal Receiver
- Two (2) Dual-Range Current Detector
- Two (2) Batteries
- Battery Charger
- Carrying Case