1 × $448.00
-
1 × $1,005.00
-
1 × $2,313.00
-
1 × $1,000.00
-
1 × $1,098.00
-
1 × $2,136.00
-
1 × $1,449.00
-
1 × $27,148.00
-
1 × $821.00
-
1 × $2,514.00
-
1 × $2,061.00
-
1 × $712.00
-
1 × $1,361.00
-
1 × $3,318.00
-
1 × $4,374.00
-
1 × $15,651.00
-
1 × $6,974.00
-
1 × $2,715.00
-
1 × $35,731.00
-
1 × $858.00
-
1 × $5,195.00
-
1 × $2,346.00
-
1 × $2,161.00
-
1 × $4,956.00
-
1 × $1,634.00
-
2 × $4,206.00
-
1 × $599.00
-
1 × $1,471.00
-
1 × $18,350.00
-
1 × $1,323.00
-
1 × $959.00
-
1 × $3,390.00
-
1 × $1,236.00
-
1 × $23,996.00
-
1 × $1,449.00
-
1 × $4,793.00
-
1 × $1,759.00
-
1 × $959.00
-
1 × $4,256.00
-
1 × $804.00
-
1 × $1,080.00
-
1 × $5,077.00
-
1 × $11,300.00
-
1 × $1,449.00
-
1 × $3,266.00
-
1 × $2,916.00
-
1 × $1,449.00
-
1 × $5,370.00
-
1 × $7,491.00
-
1 × $16,341.00
-
1 × $5,128.00
-
1 × $1,634.00
-
1 × $1,080.00
-
1 × $8,630.00
-
1 × $553.00
-
1 × $10,963.00
-
1 × $5,396.00
-
1 × $5,446.00
-
1 × $544.00
-
1 × $654.00
-
1 × $8,463.00
The MIC-5010 is a portable, rugged, easy-to-use, 5 kV class insulation test meter. The MIC-5010 has a wide measurement range, selectable test voltages, and excellent safety features.
- Measurement to 15 TΩ
- User-selectable test voltage any from 50 to 1,000 V (with 10 V resolution) and 1,000 to 5,000 V (with 25 V resolution)
- Continuous indication of measured insulation resistance or leakage current
- Audio beeps every five-second periods to indicate measurement progress
- Indication of actual test voltage during measurement
- 1.2 mA and 3 mA test current
- Step voltage insulation resistance measurement (SV)
- Selectable test times (T1, T2 , T3 from 1 to 600 seconds) to measure one or two absorption coefficients
- Adjustable measuring time to 99 59’
- Polarization index (PI) and dielectric absorption ratio (DAR) measurements
- Dielectric Discharge calculation (DD)
- High-noise immunity, digital filters function for measurements in high noise environment (10 s, 30 s , 60 s)
- Continuity measurement of protective connections and equipotential bonding in accordance with EN 61557-4
- Adjustable limits for measured resistance RISO and RCONT
- Measurement of capacitance during the measurement of RISO
- DC and AC voltage measurement in the range of 0 to 600 V
- Meter conforms to EN 61557
>
Safety First Features:
- CAT-IV 600V, CAT-III 1000V
- Automatic discharge of tested object after the insulation resistance measurement completes to remove high-voltage charge remaining due to cable capacitance
- Protection against measuring live objects, measurement will not proceed
- Measurements with test leads up to 66 ft / 20 m length
>
Construction:
- Backlit keyboard and display
- Rugged IP 54 case Protected from water spray from any direction
- Power supply from battery packs, low battery warning indicator, built-in fast charger
>
Memory Features:
- 990 cells of memory (11,880 records) to save test results
- Data transmission to a PC via USB cable