1 × $8,111.00
-
1 × $1,094.00
-
1 × $1,337.00
-
1 × $955.00
-
1 × $1,365.00
-
1 × $1,558.00
-
2 × $1,449.00
-
1 × $1,449.00
-
1 × $1,449.00
-
1 × $477.00
-
1 × $1,449.00
-
1 × $1,361.00
-
Keysight E4416A RF Power Meter: Precision Power Measurement with Front Sensor and High Sampling Rate1 × $5,390.00
-
1 × $1,164.00
-
1 × $510.00
-
1 × $5,780.00
-
1 × $846.00
-
1 × $3,393.00
-
1 × $1,273.00
-
1 × $1,052.00
-
1 × $1,005.00
-
1 × $1,449.00
-
1 × $1,634.00
-
1 × $1,449.00
-
1 × $956.00
-
1 × $2,887.00
-
1 × $1,162.00
-
1 × $2,777.00
-
1 × $1,634.00
-
1 × $2,472.00
-
1 × $681.00
-
1 × $2,262.00
-
1 × $1,549.00
-
1 × $1,969.00
-
1 × $1,792.00
-
1 × $1,382.00
-
1 × $2,170.00
-
1 × $12,017.00
-
1 × $745.00
-
1 × $1,868.00
-
1 × $508.00
-
1 × $448.00
-
1 × $603.00
-
1 × $595.00
-
1 × $1,181.00
-
1 × $5,195.00
-
1 × $1,449.00
-
1 × $1,798.00
-
1 × $1,901.00
-
1 × $1,453.00
-
1 × $6,104.00
-
1 × $6,862.00
-
1 × $1,685.00
-
1 × $1,094.00
- Select from five modules to customize the four channels as you need it
- Anyone can use this meter with its plain language screen prompts, soft keys that update for easy selection and a multilanguage interface that supports English, Spanish, French, Italian, German and Chinese
- Non-volatile memory holds up to 2000 data points with time and date stamp
- Data transfer and updating meter software is easy with two USB and RS232 ports
- Includes data analysis software for transferring stored results or displaying readings in real-time
- Mix samples without a stir plate with direct control for two Orion Star stirrer probes (096019, sold separately)
- Included electrode arm and newly-designed probe holder make it easier to maintain and place probes into samples
- Works with almost every AC power source with the included universal power adapter
- IP54-rated housing handles splashes
- Three year meter replacement warranty
- Range -2.000 to 20.000
- Resolution 0.1, 0.01, 0.001
- Relative Accuracy ±0.002
- Calibration Points up to 6
- Range 0 to 19999 in ppm, M, mg/L, %, ppb or unitless
- Resolution up to 4 significant digits
- Relative Accuracy ±0.2 mV or ±0.5% of reading, whichever is greater
- Calibration Points up to 6, Calibration point editing, timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability, adjustable ISO point
- Range ±2000.0
- Resolution 0.1
- Relative Accuracy ±0.2 mV or ±0.05% of reading whichever is greater
- Calibration Points 1
- Range -5 to 105
- Resolution 0.1
- Relative Accuracy ±0.1
- Concentration Range Polarographic: 0 to 90mg/L, 0 to 600%, RDO optical: 0 to 50mg/L, 0 to 500%
- Concentration Resolution 0.01, 0.1
- Relative Accuracy Polarographic: ±0.2mg/L, ±2% RDO optical: ±0.1mg/L up to 8mg/L, ±0.2mg/L up to 20mg/L, 10% of reading beyond, ±2%
- Calibration Water-saturated air, air-saturated water, manual (Winkler) and zero point
- Range 0.00 to 3000 mS
- Resolution 0.01 uS minimum, 4 significant figures minimum
- Relative Accuracy 0.5% reading ±1 digit
- Calibration Points up to 5
- Inputs BNC, reference pin, two 8-pin mini-DIN, 9-pin mini-DIN, two stirrer ports
- Data Management 2000 points with date/time stamp
- Output RS-232, USB
- Display Color, graphic LCD, user-customizable display
- Warranty Period 3-year meter replacement